I work on EV-charger operations for a utility subsidiary in Thailand. For a long time our DC fast chargers failed in ways the OCPP status codes never explained: the car is plugged in, the screen says "connecting", and then the session just ends. The charger reports nothing wrong.
So we started listening to the conversation itself. A DC charging session is a dialogue between the car and the charger over the charging cable: first SLAC pairing of the power-line modems (ISO 15118-3), then the DIN 70121 / ISO 15118-2 message exchange that negotiates parameters, checks isolation, pre-charges and finally delivers current. Capture that PLC/V2G traffic and you can see exactly where a session dies and which side ended it.
This post is about what those captures showed, and the open-source tool that came out of it: EV Charger Fault Detection AI (MIT).
The data
The captures come from EGAT's DC charging fleet: 212 stations, 40,542 charging sessions, 44,198 packet captures .…