I've been logging two Felicity Solar packs at 5 s resolution for about two weeks, and I don't think the balancer is doing anything useful. Something switches when balancing should start, but it is always the same channel (cell 1) on both BMSes, whichever cell is high, and the high cell is never pulled back toward the pack.
Processing img wk2ur4goq90i1...
Setup
2× Felicity Solar LiFePO4 16S, 100 Ah, 51.2 V, in parallel (DIP 1 master, DIP 2 slave)
BMS firmware 1.1 (hw 1.1). Wi-Fi/BT module firmware 2.10
Inverter: Luxpower SNA PRO-EU 6K, talking to the master over CAN
Logging: an ESP32 reads both BMSes over RS485 every 5 s. The settings come from the Wi-Fi/BT module, the same data the FSolar app shows.
BMS settings as reported by the module (identical on both packs)
Balance enabled ( balEn 1), balance start voltage 3.380 V ( balVEn )
Balance delta ( balVErr ) 65535 , i.e.…